SWMM 5 Error Messages - Format Errors
ERROR 200: | one or more errors in input file. |
This message appears when one or more input file parsing
errors (the 200-series errors) occur.
ERROR 201: | too many characters in input line. |
A line in the input file cannot exceed 1024 characters.
ERROR 203: | too few items at line n of input file. |
Not enough data items were supplied on a line of the input file.
ERROR 205: | invalid keyword at line n of input file. |
An unrecognized keyword was encountered when parsing a line
of the input file.
ERROR 207: | duplicate ID name at line n of input file. |
An ID name used for an object was already assigned to an object
of the same category.
ERROR 209: | undefined object xxx at line n of input file. |
A reference was made to an object that was never defined.
An example would be if node 123 were designated as the outlet point
of a subcatchment, yet no such node was ever defined in the study area.
ERROR 211: | invalid number xxx at line n of input file. |
Either a string value was encountered where a numerical value
was expected or an invalid number (e.g., a negative value) was supplied.
ERROR 213: | invalid date/time xxx at line n of input file. |
An invalid format for a date or time was encountered.
Dates must be entered as month/day/year and times as either decimal hours
or as hour:minute:second.
ERROR 217: | control rule clause out of sequence at line n of input file. |
Errors of this nature can occur when the format for writing control rules
is not followed correctly (see Control Rule Format).
ERROR 219: | data provided for unidentified transect at line n of input file. |
A GR line with Station-Elevation data was encountered in the [TRANSECTS] section
of the input file after an NC line but before any X1 line
that contains the transect's ID name.
ERROR 221: | transect station out of sequence at line n of input file. |
The station distances specified for the transect of an irregular cross section
must be in increasing numerical order starting from the left bank.
ERROR 223: | Transect xxx has too few stations. |
A transect for an irregular cross section must have at least 2 stations defined for it.
ERROR 225: | Transect xxx has too many stations. |
A transect cannot have more than 1500 stations defined for it.
ERROR 227: | Transect xxx has no Manning's N. |
No Manning's N was specified for a transect (i.e., there was no NC line
in the [TRANSECTS] section of the input file.
ERROR 229: | Transect xxx has invalid overbank locations. |
The distance values specified for either the left or right overbank locations
of a transect do not match any of the distances listed for the transect's stations.
ERROR 231: | Transect xxx has no depth. |
All of the stations for a transect were assigned the same elevation.
ERROR 233: | invalid treatment function expression at line n of input file. |
A treatment function supplied for a pollutant at a specific node is either not a correctly
formed mathematical expression or refers to unknown pollutants, process variables,
or math functions.